diff --git a/docs/source/hardware.rst b/docs/source/hardware.rst index 5fe2463..fdbe06a 100644 --- a/docs/source/hardware.rst +++ b/docs/source/hardware.rst @@ -40,7 +40,8 @@ Control Pilot / Proximity Pilot (X18) For ISO 15118 / DIN 70121 compliant communication between EVSE and PEV, Charge SOM supports CP (control pilot) and PP (proximity pilot) signaling including Green PHY communication. -This Green PHY communication is available on network interface ``eth1``. +This Green PHY communication is available on network interface ``eth1``. The MAC address of +this host interface is stored within the EEPROM on the Charge SOM. ********************************** High-Voltage Connector (HVDC, X19) @@ -63,7 +64,8 @@ Ethernet (X28) The X28 socket supports 10/100 Mbit/s Ethernet. In the Linux operating system it is available as network interface ``eth0``. This interface is part of a bridge -interface ``br0``. +interface ``br0``. The MAC address of this interface is stored within the OTP +of the System on Chip. ***************************** EIA-485 Interfaces (X13, X15) diff --git a/includes b/includes index 44c737d..fe996a7 160000 --- a/includes +++ b/includes @@ -1 +1 @@ -Subproject commit 44c737dfc4f5a8ca71abb2b4c402b845e45995b8 +Subproject commit fe996a74ef7d1b963754e604adf1dec9bae2200f